描述
1Modular design makes it suitable for use with output modules, sensors remote transmitters. 2Compact structure, easy to install. 3Intuitive clear reading, high reliability, measuring accuracy is 1%. 4High-definition displays show both instantaneous cumulative flow. 5Can be widely used to measure diesel, kerosene, gasoline, etc. This digital turbine flow meter has modular design, high accuracy, compact size stable performance. Easy to replace maintain internal components. Suitable for use with output modules, sensors remote transmitters. Features: Modular design makes it suitable for use with output modules, sensors remote transmitters. Compact structure, easy to install. Intuitive clear reading, high reliability, measuring accuracy is 1%. High-definition displays show both instantaneous cumulative flow. Can be widely used to measure diesel, kerosene, gasoline, etc.Specification: Operating voltage: 2.3-3.3V Battery type: 2 x AAA LRO3 batteries Thread size: 1inch NPT Repetition: 0.5% Measure accuracy: 1% Maximum working pressure: 20BAR Flow range: 10-90L / Min, 25-150L / Min, 35-250L / Min Single count: 0.00-9999.9 Total cumulative count: 0-999999 Mistakes count: 0.1000-9.9999 Working temperature: -10C - and60C(14F-140F) Stby time: 2 years Application: Diesel, kerosene, gasoline Color: Red, Blue(Optional) Weight: 371g Malfunction solution:The flow meter is not accurate. 1. The method of field calibration is not correct. Calibrate again. 2. The flow rate on the meter is below the lowest. Increase the flow rate. 3. The flow meter is blocked by the dry liquid. Take out the impeller clean it carefully make sure the impeller turns freely. 4. The impeller is wrapped by the sealing material. Remove the meter make sure the impeller turns freely. 5. Too close to the impeller. Install properly. 6. Too close to the motor or electronic noise environment Install properly. The reading numbers faded or blanked out. 1.Battery is exhausted or not connected Check the batteries or even replace them. Flow rate is normal but the meter can not count.Press the button of DISPLAY, the meter starts. 1. Field calibration is not correct. Calibrate again. 2. The impeller is blocked or damaged. Remove the meter make sure the impeller turns freely. 3.The impeller is wrapped by the sealing material. Remove the meter make sure the impeller turns freely. Flow rate is low the meter can not count.Press the button of DISPLAY, the meter starts. 1. The flow meter is blocked by the dry liquid. Take out the impeller, clean it carefully make sure the impeller turns freely. 2. The flow rate on the meter is below the lowest. Increase the flow rate. The meter can not calibrate. 1. Circuit board is break down. Replace the circuit board. 2. Button is fail to press. Replace the circuit board. Package List: 1 x Turbine Flow Meter1 x Manual Note:Please note that the new type old type of this product will be sent romly, make sure you will not mind before ordering.Increase the flow rate.
-
Fruugo ID:
413490927-873883249
-
EAN:
9100020653277