描述
Features:
<br>
<br>Writing applications in ladder language support GX-Develoer, GX-WORK2.
<br>Support for human-machine interface links, the application is exactly the same as FX3U.
<br>Support ladder programming, download, monitor.
<br>The programming port is a port for program download and communication with the human machine interface.
<br>This PLC adopts industrial-grade 32-bit MCU with strong anti-interference, and its running speed far exceeds the original FX3U.
<br>This PLC transmission baud rate is 38400.
<br>14-point input and 10-transistor output of the board.
<br>Y0-Y3 transistor can output up to 100K pulse.
<br>Y4-Y7 transistor can output up to 12K pulse.
<br>Y0-Y10 can also be used for ordinary output, which can drive stepping, solenoid valve, cylinder and other DC 24V load.
<br>The board is powered by DC 24V. Do not input AC or 220V voltage.
<br>
<br>Specification:
<br>Baud Rate:38400
<br>Power Source:24VDC
<br>Input power DC 24V
<br>Number of steps 8000 steps; 2 communication ports: 1 RS232 (DB9 serial communication port is FX3u protocol 38400, 7, E, 1; 1 RS485 (485 option) (communication protocol can be set D8120)
<br>Input point X component XO-X27, DC24 input, active low. X0-5 is the high-speed counting input port (12KHZ)
<br>Input point Y component YO-Y3 is the transistor output, the transistor output current is 500mA, plus the freewheeling diode can reach 4A; YO-Y3 is 4 channel 100K pulse output, the output current is 500mA, plus the freewheeling diode can reach 4A.; Y4~Y11 is the transistor common output Can directly drive 24V3A load
<br>Analog input 6 analog inputs, 12-bit accuracy, (3 voltages 0-10V, 3 currents 0-20MA); read analog with RD3A instructions
<br>Analog output 2 analog outputs, 12-bit accuracy, output voltage: 0-10V. Output analog voltage with WR3A command
<br>Intermediate relay M MO-M3071, the power-down storage range can be set to MO-M1023, the default M500-M1023
<br>Step point S S0-1023, the power-down storage range can be set to S0-S1023, the default S500-S9999
<br>100Ms timer TO-T199, cumulative power-down save T184-T199
<br>10Ms timer T200-T249, cumulative power-down save T246-T249
<br>1Ms timer T250-T383, where T250-255 is cumulative
<br>16-bit counter CO-C199, save power C100-199
<br>32-bit counter C200-C219, save power C220-C234
<br>32-bit high-speed counter C235-255; C235-240 is a single-phase counter, no multiplier; C241-240 is a single-phase counter, 2 times the frequency; C247-249 is a two-phase counter, no multiplier; C250-252 is a two-phase counter, 2 times Frequency; C253-255 is a two-phase counter, 4 times frequency
<br>Register D DO-D7999, the power-down storage range can be set to DO-7999.
<br>Indirect addressing pointer V, Z VO-7, Z0-7
<br>P subroutine jump number PO-63
<br>I interrupt XO-5 is interrupted outside. Timer interrupt (1MS is the unit). Counter interrupt
<br>Special M component M8000 is normally closed when running, M8002 is powered on pulse, M8011 is 10Ms pulse, M8012 is 100Ms pulse, M8013 is 1s pulse, M8014 is minute pulse.
<br>
<br>
<br>
<br>Mnemonic, name Function
<br>LD Operation starts normally open contact
<br>LDI Operation starts normally closed contact
<br>LDP Rising edge detection operation starts
<br>LDF The falling edge detection operation starts
<br>AND Series normally open contacts
<br>ANI Series normally closed contacts
<br>ANDP Check the serial connection on the upper edge
<br>ANDF Falling edge detection serial connection
<br>OR Parallel normally open contact
<br>ORI Parallel normally closed contact
<br>ORP Rising edge detected parallel connection
<br>ORF Falling edge detection parallel connection
<br>ANB Series connection between circuit blocks
<br>ORB Parallel connection between circuit blocks
<br>OUT Coil output drive
<br>SET Coil action remains
-