描述
Features:
1、SUPERIOR PERFORMANCE: High accuracy temperature and humidity measurement unit, long term stability, small volume.
2、STANDARD PROTOCOL: Standard communication protocol, communication address and baud rate can be set with special 485 circuit.
3、EASY TO INSTALL: Wall mount or rail mount. High dustproof grade (IP65). 10~30V wide voltage range power supply
4、WITH DIGITAL DISPLAY: LCD display, beautiful and generous. Button to set parameters, easy to operate.
5、 ABS MATERIAL: ABS material, sturdy and durable, long service life.
Specification:
Item Type: Temperature Humidity Transmitter
Material: ABS
Weight: Approx. 178g/6.3oz
Size: Approx. 147x88x41mm / 5.8x3.5x1.6in
Screen Size: Approx. 51x36mm / 2.0x1.4in
DC Power Supply (Default): DC 10-30V
Maximum Power Consumption: 0.4w
A Accuracy:
Humidity: ±2%RH(60%RH,25℃)
Temperature: ±0.4℃(25℃)
B Accuracy:
Humidity: ±3%RH(60%RH,25℃)
Temperature: ±0.5℃(25℃)
(Default) :
-20 Degree C To +60 Degree C, 0%rh To 95%rh (Non Condensing)
- 40 ℃ ~ + 120 ℃ Default: - 40 ℃ ~ + 80 ℃
Transmitter Circuit Operating Temperature and Humidity: 0%RH-100%RH
Probe Operating Temperature: Modbus RTU Protocol
Probe Working Humidity: 485 Signal
Agreement: 0.1 ℃
Output Signal: 0.1%RH
Temperature Display Resolution: 1s
Humidity Display Resolution: 70mm
T/h Refresh Time:
Humidity: ≤1%RH/y
Temperature: ≤0.1℃/y
Response Time:
Humidity: ≤8s (1m/s Wind Speed)
Temperature: ≤25s (1m/s Wind Speed)
Parameter Settings: Can Be Directly Modified Through Software Settings Or Buttons
Product Model:
RS: Code
WS: Temperature and Humidity Sensor
N01-485 Communication (Modbus RTU Protocol)
2D-LCD Industrial Wall Hanging (Lquid Crystal Display)
Special Wiring:
Circuit Identification Specification:
Power Supply VCC V+(10~30V DC)
Power Supply GND V-
Communication:
485 A 485 - A
485B 485-B
Basic Communication Parameters:
Password: 8 Bit Binary
Data Bit: 8 Bits
Parity Bit: Does Not Exist
Stop Bit: 1 Person
Error Checking: CRC (Cri Cyclic Redundancy Check Code)
Baud Rate: The value can be 2400bit/s, 480 bit/s, or 9600bit/s. The default value is 480 bit/s
Wiring Instructions:
Power Supply and 485 Signal
Wide Voltage Power Input Can Be 10~30V. When Connecting the 485 Signal Cable, Ensure That the Two Lines A\b Cannot Be Reversed, and the Addresses of Multiple Devices on the Bus Cannot Conflict℃)
Temperature: ±0.5℃(25℃)
(Default) :
-20 Degree C To +60 Degree C, 0%rh To 95%rh (Non Condensing)
- 40 ℃ ~ + 120 ℃ Default: - 40 ℃ ~ + 80 ℃
Transmitter Circuit Operating Temperature and Humidity: 0%RH-100%RH
Probe Operating Temperature: Modbus RTU Protocol
Probe Working Humidity: 485 Signal
Agreement: 0.1 ℃
Output Signal: 0.1%RH
Temperature Display Resolution: 1s
Humidity Display Resolution: 70mm
T/h Refresh Time:
Humidity: ≤1%RH/y
Temperature: ≤0.1℃/y
Response Time:
Humidity: ≤8s (1m/s Wind Speed)
Temperature: ≤25s (1m/s Wind Speed)
Parameter Settings: Can Be Directly Modified Through Software Settings Or Buttons
Product Model:
RS: Code
WS: Temperature and Humidity Sensor
N01-485 Communication (Modbus RTU Protocol)
2D-LCD Industrial Wall Hanging (Lquid Crystal Display)
Special Wiring:
Circuit Identification Specification:
Power Supply VCC V+(10~30V DC)
Power Supply GND V-
Communication:
485 A 485 - A
485B 485-B
Basic Communication Parameters:
Password: 8 Bit Binary
Data Bit: 8 Bits
Parity Bit: Does Not Exist
Stop Bit: 1 Person
Error Checking: CRC (Cri Cyclic Redundancy Check Code)
Baud Rate: The value can be 2400bit/s, 480 bit/s, or 9600bit/s. The default value is 480 bit/s
Wiring Instructions:
Power Supply and 485 Signal
Wide Voltage Power Input Can Be 10~30V. When Connecting the 485 Signal Cable, Ensure That the Two Lines A\b Cannot Be Reversed, and the Addresses of Multiple Devices on the Bus Cannot Conflict
Package List:
2 x Screw 2 x Expansion Tube 1 x Temperature Humidity Transmitter 1 x Instruction
-
Fruugo ID:
385188125-828257897
-
EAN:
7609253595528