AR8406 Portable Dissolved Oxygen Meter LCD Digital Dissolved Oxygen Detector Water Quality Tester
Item Type: Dissolved Oxygen Meter
Material: ASBS
Color: As shown in the picture
Model: AR8406
Battery: 1.5V AAAx4 (not included)
Application: Experimental scientific research, sewage treatment, domestic water, aquatic planting, aquaculture, medicine field
Dissolved Oxygen Correction
100% saturated dissolved oxygen correction in the air
Temperature Measurement Range
-5.0~60.0℃
Temperature Resolution
0.1℃
Temperature Accuracy
±0.5℃
Temperature Unit Switch
℃/℉
Record Data
Manually record 99 group
Salinity Compensation
0~42ppt
Altitude Compensation
0~3500m
Temperature Compensation
Automatic temperature compensation ATC
Automatic Shut-Down
Shut down after one hour of inactivity
SET button: Short press the switch and long press to enter the setting mode
CAL/ESC key: long press in measurement mode to enter calibration mode setting mode, short press to exit setting mode
Recall key: Short press to turn on or off the backlight/long press to view the saved data, press the up and down keys to view the recorded data one by one, and press the ESC key to exit the record viewing mode
To view the record data, press the ESC key to exit the record viewing mode
Mode/△ key: increase value/switch mode
Save/▽ key: Decrease the value/switch mode/measurement mode short press to save the data manually (maximum 99 records)
Enter key: confirm key
Calibration Steps:
1: Press the SET button to turn on
2: When calibrating, you need to press the Mode key to switch in the percentage "%" mode.
3: In the air medium measured value stable well to ensure that there is no water droplets or mud at the platinum place
4: Long press the "CAL/ESC" key for more than 1 second to enter the calibration, wait for a few minutes to complete the calibration automatically or manually press the "Enter" key to complete the calibration. After the calibration is completed, it is normal to display 99%~101%. If the value exceeds this value, it needs to be re-calibrated Correction.
5: Press the "Mode/▲" key to switch to the milligram/liter "mg/L" unit, and you can start the measurement.
6: Power-on display "SLO" is "normal start" (factory setting), you must wait 5~10 minutes for the reading to be stable. Power-on display "FAS" is "quick start", the reading is stable after a few seconds, and you can start measuring , But the electrolyte consumption is relatively fast; when it needs to be turned on to measure, and the water temperature is low and the response speed is slow, it can be set to "quick start". In the measurement mode, press and hold the "Recall" + "Enter" keys at the same time for more than 3 seconds to switch to "Conventional" "Start" and "Quick Start" can also be switched during setting.
7: If there is no key operation for 1 hour, it will automatically shut down; if you want to cancel the automatic shutdown, press and hold the "SET+Mode/▲"" key at the same time in the shutdown state, and the instrument will automatically shut down until the word "n" is displayed. It will continue to power on until the battery is depleted.
-