描述
DescriptionCommodity Quality Certification : ULCertification : ULFeature:DB686 HELEN+LED curing light & Light activated disinfection.DB686 HELEN+ system utilises Photo-Activated Disinfection to eliminate bacteria in the treatment of root canals, periodontal disease, peri-implantitis and caries by eliminating all species of oral bacteria on demand.DB686 HELEN+ represents a genuine advance in minimal invasive dental treatment. It provides consistent, fast, effective and simple disinfection, with no side effects.Application in Periodontal Therapy1) Thoroughly debride the site [SRP] using preferred technique2) Following control of the bleeding from instrumentation,insert the photosensitiser solution into the pocket ensuring that it penetrates to the base of the pocket. Retain the solution in the pocket for 60 seconds.3) Attach perio tip to the light guide of the 686HELEN+ handpiece. Insert the perio tip so that it is in contact with the bottom of the pocket. Then activate the light for 60 seconds.4) Review status after four weeks. The process may be repeated if necessary.Application in Peri-implantitisPeri-implantitis compromises the integrity of dental implants. The bacterial load can be reduced with the DB 686 HELEN+ technique such that normal healing may occur and help secure the stability of the implant.1. Mechanically clean the implantbody. Apply Aseptim solution liberally around (1) and throughout (2) the implant.Leave for 60 seconds andactivate the Aseptim light for 120 seconds.2. If necessary, augmentation can be done during the same session. Aseptim Plus may be used prior to implant placement to disinfect the prepared site.Application in Caries Treatment1 Isolate from saliva with cotton wool rolls and high speed aspiration or rubber dam. Remove only sufficient enamel to access the carious lesion.2 With excavator or slow running dental handpiece and round bur, remove only infected tissue. Stop immediately when resistance is felt.3. Apply Aseptim solution to the whole lesion with brush. Work into surface of infected tissue and cover the whole cavity. Continue for 60 seconds.4. Place DB686 HELEN+ handpiece tip over the site of the lesion and hold just above the cusps on the occlusal surface of the tooth.5. Activate red light for 60 seconds and hold the tip centred on the lesion. Light penetrates through the surrounding tissue to activate the Aseptim solution and disinfects the remaining lesion. If two interproximal surfaces are involved,disinfect each surface separately.6. After disinfection, either; a) fill cavity immediately with suitable restorative or b) before final filling, treat remaining softened tissue with remineralising agent. Note: glass ionomers are particularly appropriate to seal and assist in remineralisation of deep cavities.DB-686HELEN+ Muti-function:LED curing light & light activated disinfectionTwo light sourceAutomatically identify the blue and red light.
-
Fruugo ID:
172380651-368494014
-
EAN:
4843227183790