描述
VU Meter Features:Standard test conditions temperature: 20 Celsius, humidity 70% . Can also be tested under normal temperature and humidityThe influenza degree pointer at the zero scale to the maximum scale sensitivity of 1000 10% (full scale position);Internal impedance :800 ohm 10%;Insulation impedance meter outside the box plus the electrical circuit with 500V DC plus 50M ohm meter shell
Electrical insulation of the circuit impedance is 500V DC voltage test of the insulation value. Pointer to overlap with the zero-scale tolerance of 1mm balanced meter using a standard position and tilt 90 degrees to allow the error range of 1mm;Pointer to mount the current plus three times the full scale current, and slowly reduced to the the electric influenza degree 1/2 reading,
The pointer will return to the scale plate within 1/3 scale friction meter coupled with the current, and slowly increase or decrease to a certain value, indicating the point of error range of 1mm,Brake instantly plus scale plate 2/3 of the current value of the pointer indicates the location of the time required for a second or less.
VU Meter Special Test:Tests on each interval of five seconds to ten times the full scale current input overload, the action is repeated nine times for each time of 05 seconds .After this test, 7-14 to maintain normalVibration test meter packaged in the vibration plate 1,000 times per minute, up and down 4mm shock In each direction for 10 minutes.
After this test 7-14 to maintain normal impact test meter packaged 30-cm height of fall in 3cm thick wooden board, three-direction testAfter this test, 7-14 to maintain normal reliability test the current input of 100,000 calibration points within the limits of current sense is still the standard environmental impact test temperature of 50 Celsius, humidity 85%, for 100 hours, after s test 7-14 to maintain normal.
Terminal pull test: terminals must withstand one kilogram tension, sustained 60 seconds will not be affected.
VU Meter Others:
Using the temperature limits: -10 Celsius to +60 Celsius RH 35 to 85%
Storage temperature limits: -20 Celsius to +60 Celsius RH 35 to 85%
Do not use the meter in direct sunlight, and PUT the meter in the box to avoid foreign matter into the meter internal.
Soldering Condition terminal about 3 mm placed in the temperature of 230 Celsius tin plate, placed 35 seconds.
After this test, 7-14 to maintain normal,
Hand-held soldering to solder temperature 350 Celsius, the terminal contact for 35 seconds, the terminal front-end of about 3mm contact with the solder .
After this test, 7-14 to maintain normal,
Anti-static test in the same direction three times, to characterize the difference between the pointer in the length of the scale in a transparent cover surface to dry nylon 1/3 back to the zero position.
Bulb size: 4 blue LED backlighting, parallel to the PCB (30-32V 80mA)VU Meter
The direction of the pointer swing: left to right
Pointer length: 70 1 mm from the center axis to the needle end
Pointer width: 045 005 mm
Colour:Black + Blue
Material:Zinc cupronickel
Size:134x95x45cm
Package Contents:
1 x VU level meter
Only the above package content, other products are not included.
Note: Light and different displays may cause the color of the item in the picture a little different from the real thing. The measurement allowed error is +/- 1-3cm.
-
Fruugo ID:
116622415-244906408
-
EAN:
4712552709503