描述
DT‑9960H Multimeter Digital LCD Universal Tester NCV Testing with Overload Protection for Electricity Testing
DT‑9960H Multimeter Digital LCD Universal Tester NCV Testing with Overload Protection for Electricity Testing
Item Type: Multimeter
Model: DT-9960H
Material: ABS
Battery: 1 x 9V 6F22(battery not included)
Purpose: This product can be widely used in residential, industrial factories, tenement, office buildings, home appliance equipment maintenance and testing and other industries
Impact Resistance (Drop Test): 2 meters
Continuity Test: if the resistance is ≤50Ω, the buzzer will sound, and the test current is <0.35mA
Input Impedance: Approximately:> 10M
True RMS: AC response
The crest factor ≤3 can reach up to 500V at full scale, and the crest factor is reduced to ≤1.5 at 1000V
Display: 6000 digit backlit LCD with analog bar graph
Over Range: display "OL"
Automatic Shutdown: the meter will automatically shutdown after about 15 minutes without operation (can be disabled)
Polarity: automatically distinguish the polarity, (-) negative indication
Measurement Speed: 3 times per second under normal conditions
Fuse: mA, uA range: 800mA/1000V ceramic fast-blow
A Range: 10A/1000V ceramic fast fusing
Working Temperature: 0℃~50℃ (32℉~122℉)
Storage Temperature: -10℃~60℃ (14℉~140℉)
Working Humidity: maximum 80% at 31℃ (87℉), and linear drop to 50% at 40℃ (104℉)
Storage Temperature: <80%RH
Working Altitude: 2000 meters
How e: 1. DC voltage measurement
1. Set the function switch to the VDC position.
3. Touch the tip of the black test lead to the negative pole of the circuit; touch the tip of the red test lead to the positive pole of the circuit.
1. Set the function switch to the V/Hz/%/VFD position and indicate "AC" on the display. Alternating current
3. Touch the tip of the black test lead to the negative pole of the circuit; touch the tip of the red test lead to the positive pole of the circuit.
5. Press and hold the MODE button for 2 seconds, "VFD" will be indicated on the display.
6. Read the VFD value on the display.
7. To exit the VFD mode, press and hold the MODE button for 2 seconds.
8. Press the Hz/% button to indicate "Hz".
9. Read the frequency on the display.
10. Press the Hz/% button again to indicate "%".
11. Read the percentage of duty cycle on the display.
1. Set the function switch to the m//Hz/% position.
2. Press the MODE button to indicate "DC" or "AC".
4. Touch the tip of the black test lead to the negative pole of the circuit; touch the tip of the red test lead to the positive pole of the circuit.
6. Press the Hz/% button to indicate "Hz".
7. Read the frequency on the display.
8. Press the Hz/% button again to indicate "%".
9. Read the percentage of duty cycle on the display.
4. Low impedance measurement
1. Set the function switch to LoZ, the LCD display will display the symbols "LoZ" and "AC".
3. Touch the tip of the black test lead to the negative pole of the circuit; touch the tip of the red test lead to the positive pole of the circuit.
DC Voltage
60.00mV
0.01mV
±(0.9%+9digits)
600.0mV
0.1mV
6.000V
0.001V
±(0.5%+5digits)
60.00V
0.01V
600.0V
0.1V
1000V
1V
±(0.6%+6digits)
AC Voltage(45~1kHz)
60.00mV
0.01mV
±(0.9%+9digits)
600.0mV
0.1mV
6.000V
0.001V
±(0.8%+4digits)
60.00V
0.01V
600.0V
0.1V
1000V
1V
±(0.8%+8digits)
Low Impedance AC voltage
6.000V
0.001V
±(3.0%+30digits)
60.00V
0.01V
600.0V
0.1V
VFD
50.0V~700V
0.1V/1V
±(4.0%+9digits)
DC Current
600.0μA
0.1μA
±(1.0%+3digits)
6000μA
1μA
60.00mA
0.01mA
600.0mA
0.1mA
6.000A
0.001A
±(1.5%+3digits)
10.00A
0.1A
AC Current
600.0μA
0.1μA
±(1.5%+3digits)
6000μA
1μA
60.00mA
0.01mA
600.0mA
0.1mA
6.000A
0.001A
±(2.0%+3digits)
10.00A
0.1A
Resistance
600.0Ω
0.1Ω
±(1.0%+2digits)
6.000kΩ
0.001kΩ
±(0.8%+2digits)
60.00kΩ
0.01kΩ
600.0kΩ
0.1kΩ
6.000MΩ
0.001MΩ
±(1.2%+2digits)
60.00mΩ
0.01mΩ
±(1.0%+5digits)
Capacitance
6.000nF
0.001nF
in a relative state ±(5.0%+25digits)
60.00nF
0.01nF
±(5.0%+20digits)
600.0nF
0.1nF
±(40%+5digits)
6.000μF
0.001μF
60.00μF
0.01μF
600.0μF
0.1μF
6.000mF
0.001mF
±(10%reading)
60.00mF
0.01mF
-
Fruugo ID:
412914540-872900965
-
EAN:
4641337003676