描述
Feature:1. Small in size and light in weight, easy to carry and assemble, 8 directions and easy to operate.2. It is made of polycarbonate housing, which has high mechanical strength, high hardness, corrosion resistance and rust resistance.3. Antiexposure, high impact strength, long service life, suitable longterm use in outdoor environments.4. With the internal smooth bearing system, the accuracy of information collection is effectively ensured and the use is more convenient.5. Highperformance bearings, low rotational resistance, accurate measurement, antielectromagnetic interference treatment, can be applied to both fourwire and threewire connection.Specification:Condition: 100% Brand NewItem Type: Wind Direction SensorMaterial: PolycarbonateWide Voltage: 10-30V DC Power InputApplication: Widely used in the measurement of wind direction in greenhouses, environmental protection, weather stations, ships, wharf, breeding and other environments.v\:* {behavior:url(#default#VML);}o\:* {behavior:url(#default#VML);}x\:* {behavior:url(#default#VML);}.shape {behavior:url(#default#VML);}Parameter:DC Power Supply (Default)10-30V DCMaximum Power ConsumptionVoltage Output1.2WTransmitter Circuit Operating Temperature-20 to +60, 0%RH-80%RHDynamic Response Time0.5sOutput SignalVoltage Output0-5VLoad CapacityVoltage OutputOutput Resistance 600Calculation Method:0-5V Output Comparison TableOutput Value (V)Corresponding Wind Direction0North Wind0.7143Northeast Wind1.4286East Wind2.1429Southeast Wind2.8571South Wind3.5714Southwest Wind4.2857West Wind5Northwest WindProduct Size: Approx. 23.5 x 18.5 cm / 9.3 x 7.3 inWeight: Approx. 315g / 11.1ozCommon Problems and Solutions:No output or output error possible causes:1) The range corresponding error causes the error PLC calculation. Please refer to the technical indicators for the range.2) The wiring method is incorrect or the wiring sequence is wrong.3) The power supply voltage is incorrect (24V power supply for 0-10V type).4) The distance between the transmitter and the collector is too long, causing signal disturbance.5) The PLC collection port is damaged.6) Equipment damage.Package List:1 x Wind Direction Sensor1 x Cable1 x Screw Kit (4 x Screw, 4 x Nut)Note:1. The user should not disassemble it by himself, and should not touch the sensor core to avoid damage to the product.2. Keep away from high-power interference equipment as much as possible to avoid inaccurate measurement, such as inverters, motors, etc. When installing or disassembling the transmitter, the power must be disconnected firstly, and water in the transmitter can cause irreversible changes.3. Prevent chemical agents, oil, dust, etc. from directly invading the sensor, do not use it for a long time under condensation and extreme temperature environment, and prevent cold and heat shock.
-
Fruugo ID:
420602329-886223315
-
EAN:
7847689943814