For 2 Channel Isolated Rs485 Repeater Industrial Grade Photoelectric Isolation Type Repeater Module

$79.00
免费送货

For 2 Channel Isolated Rs485 Repeater Industrial Grade Photoelectric Isolation Type Repeater Module

  • 品牌: Unbranded

For 2 Channel Isolated Rs485 Repeater Industrial Grade Photoelectric Isolation Type Repeater Module

  • 品牌: Unbranded
建议零售价: $169.00
价格: $79.00
您节省了: $90.00 (53%)
由……售出:
$79.00
免费送货

有货

14天退货政策

我们接受以下付款方式

描述

For 2 Channel Isolated Rs485 Repeater Industrial Grade Photoelectric Isolation Type Repeater Module

Fangrui Product Details 1. 2 Channel Isolated Rs485 Repeater Industrial Grade Photoelectric Isolation Type Repeater Module 936vdc 2. Item Type: Repeater Module 3. Material: Pp 4. Operating Voltage 5. Typical Value: Dc 9-36v 6. Limit Value: Dc Dc40v 7. Power Rating 8. Typical: 0.36w (9v/35ma; 12v/27ma; 24v/15ma) 9. Limit Value: 0.5w 10. Operating Environment 11. Typical: Temperature: -30 To 80 Humidity: >rh 12. Limit Value: -40 To 85 13. Isolation Voltage 14. Typical: 2000v 15. Limit Value: 2500v 16. Interface Protection 17. Typical: 600w Thundersurge 18. Limit: 600w 19. Load Capacity 20. Typical: 1-128 Nodes 21. Limit: 256 Nodes 22. Communicating Distance 23. Typical: 0-1500m 24. Limit: 2000m 25. Communicating Speed 26. Typical: 300bps-115.2kbps 27. Limit Value: 300kbps 28. Size: Approx. 100 X 54 X 32mm / 3.9 X 2.1 X 1.3in 29. The Meanings Of The Status Indicators On The Front Are As Follows: 30. Power Indicator: Red Power Indicator, On After Power On 31. Data Indication: Green Data Indicator, Blinking When There Is Data On The Bus 32. The Interface At The Terminal Of The Wiring Column Is Defined As Follows 33. Vcc: Power Supply Interface (dc 9-36v) 34. Gnd: Negative Power Supply Terminal 35. 485 A: Rs485 Signal Input Or Output Positive Terminal 36. 485 B: Rs485 Signal Input Or Output Negative 37. 485 A2: Second Rs485 Signal Input Or Output Positive 38. 485 B2: Second Rs485 Signal Input Or Output Negative 39. Gnd: Isolated Rs485 Terminal Ground, Can Be Connected To Earth Or Shielding Wire 40. 485 A1: First Rs485 Signal Input Or Output Positive 41. 485 B1: First Rs485 Signal Input Or Output Negative 42. How E: 43. A. 485 Wiring Notes: 44. 485 Communicating Line Must Be Shielded Twisted Pair, Preferably With Multiple Spare Strands, And The Total Length Is Recommended Not To Exceed 1500 Meters. 45. The Wiring Should Be As Far Away As Possible From The High Voltage Power Lines, Not In Parallel With The Power Lines, And Not Bundled Together. 46. 485 Bus Must Be A Hand In Hand Bus Structure, Firmly Eliminate The Star Connection And Bifurcation Connection. 47. More Than 30 Controllers Or Line Longer Than 500 Meters, It Is Recommended That The 485 Repeater Must Be Used. 48. Ac Powered Equipment And Chassis Must Be Real Grounded, And Well Grounded. 49. Connect The Gnd Ground Of All 485 Devices With Shielded Wire. 50. B. Communicating Using Rs485 Bus Wire Selection Requirements: 51. Use 2-core Shielded Twisted Pair Wire 52. Copper, Wire Diameter 0.5 - 0.75 Square Millimeters. 53. Impedance 38 - 88 Ohms / Km. 54. Capacitive Resistance Of 30 To 50 Nf/km. 55. Stranding Distance Of 20 Mm Of 2 Core Shielded Twisted Pair (if The Distance Of The Line Does Not Exceed 500 Meters Can Be Appropriately Reduced Line Standards, But Must Be Twisted Pair) 56. C. Bus Limits: 57. Composed Of Two Or More Devices With Physical Connection To Each Other, A Maximum Of 256 Devices Are Allowed To Be Hooked Up On The Bus, And The Bus Length Is No More Than 1500 Meters Without Adding Repeaters. The System Bus Should Not Have Branches, And If Branches Are Unavoidable, The Following Requirements Must Be Met: 58. The Branch Length Is No More Than 10 Meters; The Sum Of The Bus Length Is No More Than 800 Meters; The Total Number Of Devices On The Branch Line Is Recommended To Be No More Than 50. 59. All Communicating Signal Lines Should Be As Far Away From The Source Of Interference As Possible, Signal Lines Should Go To The Weak Well, Not With Strong Power (such As 220 Volt Residential Power) Or Rf Signal Lines (such As Catv, Large Signal Audio Lines) Parallel Lines, If Parallel Lines, The Distance Should Be Greater Than 0.5 Meters. 60. All Line Joints Must Be Welded Or Doweled Tight Connection, And Waterproof Treatment, For Example, The Butt Welded With Waterproof Tape Or Epoxy Resin Sealing Treatment. 61. D. Signal Common Ground: 62. All Devices On The Same Net Segment Must Have A Unified Signal Ground To Avoid Common Mode Interference. 63. Centralized Power Supply, All The Power Supply On The Same Net Segment (including Communicating Equipment With Their Own Power) Of The Negative Dc Terminal Directly Connected Together To Form A Common Signal Ground, The Signal Ground Is The Dc Power Ground. 64. When A Single Independent Power Supply, The Ground (black Line) Pins Of All Bus Devices On The Same Net Segment Are Connected Together, Thus Forming A Common Signal Ground.
  • 品牌: Unbranded
  • 类别: 网络中继器
  • 颜色: Specialty Electrical Switches & Relays
  • Fruugo ID: 445373078-935287274

配送 & 退货

在 24 小时内发货

  • STANDARD: 免费 - 之间的交付 周五 26 十二月 2025–周五 02 一月 2026 - 免费

从 中国 送货。

我们会争取将您订购的产品按照您的规格完整地配送给您。不过,万一您收到不完整的订单,或收到的产品与您订购的不同,或者有其他原因让您对订单不满意,您可以要求全部或部分退货,您将收到相应产品的全额退款。 查看完整的退货政策

产品合规详细信息

请参阅下面概述的针对该产品的合规性信息。

以下信息由销售该产品的独立第三方零售商提供。

制造商:
以下信息概述了在Fruugo销售的相关产品的制造商联系信息。

  • Shenzhen Momogui Trading Co., Ltd
  • Shenzhen Momogui Trading Co., Ltd
  • 603 Sha Hao Building, Minzhi Community, Minzhi Street,Longhua District
  • Shenzhen
  • GuangDong
  • China
  • 518110
  • joelen@timeswhale.com
  • 86-13927089892
  • https://www.ecrep.es/

欧盟负责人:
以下信息概述了欧盟负责人的联系信息。该负责人是位于欧盟的指定经济运营者,负责有关销售到欧盟的相关产品的合规义务。

  • EC REP SERVICES SL
  • EC REP SERVICES SL
  • CALLE GRAN VIA 49, 7 DCH.
  • MADRID
  • ES
  • 28013
  • ECREPSERVICE@HOTMAIL.COM
  • һ34 682797075
  • https://www.ecrep.es/