LCD Digital Audiometer Professional Adult Hearing Screening Instrument Pure Tone Audiometer for Hearing Test with Response Switch Handle 100240V EU Pl

$3,499.00
免费送货

LCD Digital Audiometer Professional Adult Hearing Screening Instrument Pure Tone Audiometer for Hearing Test with Response Switch Handle 100240V EU Pl

  • 品牌: Unbranded

LCD Digital Audiometer Professional Adult Hearing Screening Instrument Pure Tone Audiometer for Hearing Test with Response Switch Handle 100240V EU Pl

  • 品牌: Unbranded
建议零售价: $4,549.00
价格: $3,499.00
您节省了: $1,050.00 (23%)
由……售出:
$3,499.00
免费送货

有货

我们接受以下付款方式

描述

Feature:1. HIGH ACCURACY: Pure tone audiometer offers continuous attenuation with a step size of 5dB, ensuring a precision of less than 1dB.2. ADVANCED TECHNOLOGY: Utilizing advanced technology and algorithms, it accurately identifies and measures sounds within different frequency ranges, providing accurate hearing evaluations.3. MULTIFUNCTIONAL: Audiometer can be used for hearing assessment, screening, and training. Users can choose different modes and perform corresponding operations based on their specific needs.4. CONVENIENT AND USER FRIENDLY: With high accuracy and multifunctionality, it is easy to use and helps users gain a comprehensive understanding of their hearing condition, enabling them to take appropriate protective and improvement measures.5. VERSATILE USAGE: The pure tone audiometer can be used as a fixed installation device. It is suitable for institutions such as hospitals, disease control centers, community centers, industrial enterprises, driving schools, and rehabilitation centers for conducting hearing assessments.Specification:Item Type: Pure Tone AudiometerMaterial: MetalApplicable Range: For individuals with response ability for hearing threshold detectionPartial Performance Specifications are as follows:Test Frequency: Air Conduction (2508000) Hz, Bone Conduction (2506000) Hz, error less than 2%;Test Strength Range: Air Conduction (-10120) dB, Bone Conduction (-1070) dB;Masking Strength Range: (-10110) dB;Distortion: Air Conduction less than 2.5%, Bone Conduction less than 5.5%;Accuracy: Continuous Attenuation/Step 5dB, error less than 1dB.Power Requirement: AC100-240V 50/60Hz 30VAThe working environment temperature of the instrument must be between 15 and 35, relative humidity must be between 30% and 90%, atmospheric pressure must be between 98kPa and 104kPa. Extreme temperatures, humidity, and altitude can all affect the performance of this device.How to Use: 1) Before installing and using the device, please ensure that the surrounding environment is quiet and clean, and keep away from radioactive electromagnetic fields and electronic devices.2) After connecting, power on the device by pressing the green switch button located at the lower right front of the panel. The display screen will turn on and automatically enter pure tone testing.3) Familiarize the subject with the testing procedure.Demonstrate the testing procedure by presenting a test tone of 1000Hz at 40dB HL strength to the subject ear. If the subject can hear the tone, reduce the strength by 40dB. If the subject cannot hear the tone, increase the strength by 40dB until the subject can hear the sound. Then, reduce the strength to the lowest level and gradually increase the sound strength until the subject responds. After a 2-3 second interval, provide the sound again for 2-3 seconds. If the response is consistent, formal testing can proceed.(1) Air Conduction Audiometry (AC)The purpose of air conduction audiometry is to determine the auditory sensitivity at different frequencies. This test can assess air conduction loss but cannot differentiate between conductive hearing loss and sensorineural hearing loss. Air conduction thresholds involve the entire auditory system, including the conductive components of the outer and middle ear, as well as the cochlea and the integrity of the auditory nerve function. It is the fundamental part of audiology evaluation.A) The pure tone audiometer will automatically enter air conduction testing after powering on.B) Position the headphones and ask the subject to remove glasses and jewelry. Place the headphones from the top down and adjust the earmuffs so that the headphones' speaker is directly aligned with the ear canal. Adjust the headband length to ensure that the headphones are secure. If the earmuffs do not contact the ears tightly, there may be significant errors in the low frequency testing results.C) Instruct the subjectBefore the testing begins, explain to the subject about the testing pure tones and the patient response handle button. You will hear different sounds of different strengths through the headphones. When you hear the sound, press the patient response handle button. When you do not hear the sound, release the patient response handle button.D) Order of tested frequencies1000Hz, 1500Hz, 2000Hz, 3000Hz, 4000Hz, 6000Hz, 8000Hz, 250Hz, 500Hz, 750Hz, 1000Hz. Generally, start with the better ear or the healthy ear. If there is a difference of more than 10dB in the thresholds between two 1000Hz tests, retesting should be done. If the thresholds of two octave frequencies differ by 20dB, half octave frequency threshold measurement should be performed. The duration of sound presentation should be 2-3 seconds, and the interval between the presentations should not be shorter than the presentation time. This is because the complete recovery time after adaptation is usually 2-3 seconds, and the presentation time and interval should be irregular. Continuous pure tone testing should
  • 品牌: Unbranded
  • 类别: 卫生
  • Fruugo ID: 326026264-721624848
  • EAN: 7598390762743

产品安全信息

请参阅下面列出的特定于该产品的产品安全信息

以下信息由销售该产品的独立第三方零售商提供。

产品安全标签

CE Mark
安全警告: Warning: Please read the product instructions carefully before use to ensure correct use.
序列号: 7598390762743

配送 & 退货

在 2 天内发货

  • STANDARD: 免费 - 之间的交付 周五 24 十月 2025–周四 30 十月 2025 - 免费

从 中国 送货。

我们会争取将您订购的产品按照您的规格完整地配送给您。不过,万一您收到不完整的订单,或收到的产品与您订购的不同,或者有其他原因让您对订单不满意,您可以要求全部或部分退货,您将收到相应产品的全额退款。 查看完整的退货政策

产品合规详细信息

请参阅下面概述的针对该产品的合规性信息。

以下信息由销售该产品的独立第三方零售商提供。

制造商:
以下信息概述了在Fruugo销售的相关产品的制造商联系信息。

  • Shenzhenshimutalaikejiyouxiangongsi
  • Shenzhenshimutalaikejiyouxiangongsi
  • 71001-187, 7/F, Building D, Gaoke Mansion, No. 2076 Yuanyuan Avenue
  • Nanshan Street
  • Nanshan District
  • Shenzhen
  • CN
  • 518000
  • gbyhynnygt@126.com
  • 18664978705
  • https://detail.1688.com/offer/593788918206.html?spm=a2615.7691456.autotrace-offerGeneral.7.4cc915345wLsDx

欧盟负责人:
以下信息概述了欧盟负责人的联系信息。该负责人是位于欧盟的指定经济运营者,负责有关销售到欧盟的相关产品的合规义务。

  • None
  • Kequ Technology s.r.o.
  • Pražákova 1008/69
  • Štýřice
  • Jihomoravský kraj
  • Brno
  • CZ
  • 63900
  • christopher25106@outlook.com
  • 420608214795
  • https://www.noon.com/uae-en/p-29378/