LCD Voltage Current Combo Meter Resin Energy Saving Wattmeter for Household Appliances200A
Item Type: LCD Combo Meter Voltage
Material: Resin
Input Voltage
Measuring Range When Self-Powered: 6-75V
Measurement Range When External Power Supply: 0-120V
External Power Supply Voltage: 6-60V
Display Mode: 1.8 Inch LCD Display
Measuring Range
Voltage: 0.01-120V
Capacity: 0.001AH-65000AH
Energy: 0.00KWH-99999.9kWh
Time: 0-100 Hours
Power Value: 99KW
Temperature: 1-100 Degrees Celsius
Accuracy
Voltage: ±1%
Current: ±2%
Temperature: ±1 Degrees Celsius
Measurement Rate: 5 Times/Sec
Type and Scope of Protection
OVP (Over Voltage Protection): 0.01-500V
LVP (Undervoltage Protection): 0.01-500V
OCP (Charge Overcurrent Protection): 0-1000A
NCP (Discharge Overcurrent Protection): 0-1000A
OTP (Over Temperature Protection): 0-100 Degrees CelsiusFeatures
1. "BAT" battery capacity value setting, this parameter is to set the measured total capacity of the battery.
2. "BPC" battery remaining capacity percentage, you can set the remaining battery AH number according to this value.
3. "OVP" sets the over-voltage protection value. If the OVP value is set, when the actual measured voltage value is greater than the set value, it will prompt over-voltage and cut off the relay (self-distribution).
4. "LVP" sets the overvoltage protection value. If the LVP value is set, when the actual measured voltage value is less than the set value, it will prompt undervoltage and cut off the relay (self-equipped)
5. "NCP" sets the over-voltage protection value. If the NCP value is set, when the actual measured charging current value is less than the set value, it will prompt over-current and cut off the relay (self-equipped)
6. "OCP" sets the over-voltage protection value. If the OCP value is set, when the actual measured discharge current value is less than the set value, it will prompt over-current and cut off the relay (self-equipped)
7. "OTP" sets the over temperature protection value. If the OTP value is set, when the actual measured temperature value is greater than the set value, the over temperature will be prompted and the relay will be cut off (self-equipped)
8. "ADS" communication address code setting. In multi-machine communication, multi-machine communication can be realized by setting the address code differently.
9. "TTL" The default relay output state when the instrument is powered on, normally open or normally closed.
10. "CLR" no-load current clearing function, if the actual no-load current is zero. 11. "DTE" screen time setting, if this time value is set, the meter will automatically turn off the screen and press the OK button to automatically light up.
-