描述
  Features
1. Input point X element x0-x7, DC24 input, low level valid. X0-5 is the high-speed counting input port (default: 12K,100KHZ optional).
2. Output analog voltage WR3A instruction, corresponding to the value 0-4095.
3. The maximum speed current is 1A. External load common terminating + 24, the other end received the PLC output port Y.
4. Y0-Y5 is optional relay or transistor output, relay output current 5A. The transistor output DC24V, the current maximum 1A.
5. Intermediate relay M: M0-M3071, the power loss preservation range can be set.
Features: 
 Input point X element x0-x7, DC24 input, low level valid. X0-5 is the high-speed counting input port (default: 12K,100KHZ optional). 
 Output analog voltage WR3A instruction, corresponding to the value 0-4095. 
 The maximum speed current is 1A. External load common terminating + 24, the other end received the PLC output port Y.  
 Y0-Y5 is optional relay or transistor output, relay output current 5A. The transistor output DC24V, the current maximum 1A.  
 Intermediate relay M: M0-M3071, the power loss preservation range can be set. 
  
 Specification: 
 Weight: 239g/8.4oz 
 Input point:8  
 Output point:6  
 Power supply voltage: DC24V  
 Output current: 5A  
 Analog input: 6AD  
 Analog output: 2DA  
 High speed count:6 road 12K optional 100K  
 Pulse output: No  
 Floating point: Support  
 Step motor: No support  
 Memory capacity:8000 step  
 Programming software: GX developer or GX works  
 Program steps: 8000 steps 
 Two communication ports:  
 One RS232 (DB9) serial communication port is FX3u protocol 38400,7, E, 1;  
 One RS485 (485 optional configuration) (communication protocol can be set to D8120). 
 The output point Y element:  
 Y0-Y5 is optional relay or transistor output, relay output current 5A. The transistor output DC24V, the current maximum 1A.  
 Y0-1 is high-speed output port (maximum 100K). PWM period is 0-32767US. High  
 The maximum speed current is 1A. External load common terminating + 24, the other end received the PLC output port Y.  
 Analog input:  
 Six-way analog input,12 bit accuracy, input voltage:0-10V,0-20MA; Read the analog quantity with RD3A directive. The corresponding values 0-4095. Two-way potentiometer analog input, D8030, D8031.  
 Analog output: 
 2-channel analog output, 12-bit accuracy, output voltage: 0-10v. Output analog voltage WR3A instruction, corresponding to the value 0-4095. 
 Intermediate relay M: M0-M3071, the power loss preservation
Package List
  
  
  
      - 
          Fruugo ID: 
          397203936-847492332
      
 
      - 
          EAN: 