Features:_x000D_
_x000D_
Input point X element x0-x7, DC24 input, low level valid. X0-5 is the high-speed counting input port (default: 12K,100KHZ optional). _x000D_
Output analog voltage WR3A instruction, corresponding to the value 0-4095. _x000D_
The maximum speed current is 1A. External load common terminating + 24, the other end received the PLC output port Y. _x000D_
Y0-Y5 is optional relay or transistor output, relay output current 5A. The transistor output DC24V, the current maximum 1A. _x000D_
Intermediate relay M: M0-M3071, the power loss preservation range can be set. _x000D_
_x000D_
Specification:_x000D_
Weight: 239g/8.4oz_x000D_
Input point:8 _x000D_
Output point:6 _x000D_
Power supply voltage: DC24V _x000D_
Output current: 5A _x000D_
Analog input: 6AD _x000D_
Analog output: 2DA _x000D_
High speed count:6 road 12K optional 100K _x000D_
Pulse output: No _x000D_
Floating point: Support _x000D_
Step motor: No support _x000D_
Memory capacity:8000 step _x000D_
Programming software: GX developer or GX works _x000D_
Program steps: 8000 steps_x000D_
Two communication ports: _x000D_
One RS232 (DB9) serial communication port is FX3u protocol 38400,7, E, 1; _x000D_
One RS485 (485 optional configuration) (communication protocol can be set to D8120)._x000D_
The output point Y element: _x000D_
Y0-Y5 is optional relay or transistor output, relay output current 5A. The transistor output DC24V, the current maximum 1A. _x000D_
Y0-1 is high-speed output port (maximum 100K). PWM period is 0-32767US. High _x000D_
The maximum speed current is 1A. External load common terminating + 24, the other end received the PLC output port Y. _x000D_
Analog input: _x000D_
Six-way analog input,12 bit accuracy, input voltage:0-10V,0-20MA; Read the analog quantity with RD3A directive. The corresponding values 0-4095. Two-way potentiometer analog input, D8030, D8031. _x000D_
Analog output:_x000D_
2-channel analog output, 12-bit accuracy, output voltage: 0-10v. Output analog voltage WR3A instruction, corresponding to the value 0-4095._x000D_
Intermediate relay M: M0-M3071, the power loss preservation range can be set._x000D_
Step point S: S0-1023, power off storage range can be set to S0-S1023_x000D_
100Ms timer: t0-t199, accumulative power off save t184-t199_x000D_
10Ms timer: T200-T249, accumulative power off saving T246-T249_x000D_
1Ms timer: T250-T383, where T250-255 is cumulative_x000D_
16-bit counter: C0-C199, power off to save C100-199_x000D_
32-bit counter: C200-C219, power off to save C220-C234_x000D_
32-bit high-speed counter: C235-255; C235-240 is a single-phase counter, not frequency doubling; C241-240 is a single-phase counter with double frequency; C247-249 is a two-phase counter, not frequency doubling; C250-252 is a two-phase counter with double frequency; C253-255 is a two-phase counter, 4 times frequency;_x000D_
Register D: D0-D7999, power off save range can be set to d0-7999,_x000D_
Indirection pointer V, Z: V0-7, Z0-7_x000D_
P subroutine jump number: P0-63_x000D_
I interrupt: X0-5 external interrupt. Timer interrupt (1MS). The counter is interrupted._x000D_
Special M components: M8000 is normally closed when running, M8002 is electric pulse, M8011 is 10Ms pulse, M8012 is 100Ms pulse,M8013 is 1s pulse,M8014 is minute pulse._x000D_
_x000D_
Package List:_x000D_
1x PLC Control Board
-
Fruugo ID:
321540548-713429220
-
EAN:
1277520027285