描述
Features: Input point X element x0-x7, DC24 input, valid low level. X0-5 is the high-speed counting input port (default: 12K, 100KHZ optional). WR3A analog voltage output instruction, corresponding to the value 0-4095. The maximum speed current is 1A. Common external load completed +24, the other end received PLC output port Y. Y0-Y5 is optional relay or transistor output, relay output current 5A. The transistor output DC24V, the maximum current 1A. Intermediate relay M: M0-M3071, power loss retention range can be set. Specifications: Weight: 239g / 8.4oz Input point: 8 Output point: 6 Power supply voltage: DC24V Current output: 5A Analog input: 6AD Analog output: 2DA High speed counting: 6 road 12K optional 100K output Pulse: No Floating point: Support Stepper motor: No support Memory capacity: 8000 steps Programming software: GX developer or GX works Program steps: 8000 steps Two communication ports: One RS232 serial communication port (DB9 ) is FX3u protocol 38400,7,E,1; One RS485 (optional configuration 485) (communication protocol can be set to D8120). Output point element Y: Y0-Y5 is optional relay or transistor output, relay output current 5A. The transistor output DC24V, the maximum current 1A. Y0-1 is a high speed output port (maximum 100K). The PWM period is 0 to 32767US. High The maximum speed current is 1A. Common external load completed +24, the other end received PLC output port Y. Analog input: Six-way analog input, 12-bit precision, input voltage: 0-10V, 0-20MA; Read the analog quantity with the RD3A directive. Corresponding values 0-4095. Bidirectional potentiometer analog input, D8030, D8031. Analog output: 2 channel analog output, 12-bit precision, output voltage: 0-10v. WR3A analog voltage output instruction, corresponding to the value 0-4095. Intermediate relay M: M0-M3071, power loss conservation range can be set. Step point S: S0-1023, power off storage Range can be set to S0-S1023 100Ms timer: t0-t199, accumulated power off saving t184-t199 10Ms timer: T200-T249, power off timer cumulative power off T246-T249 1Ms timer: T250-T383, where T250-255 is cumulative 16-bit counter: C0-C199, power off to save C100-199 32-bit counter: C200-C219, power off to save C220- C234 32-bit high speed counter: C235-255; C235-240 is a single phase meter, not frequency doubling; C241-240 is a single-phase dual-frequency meter; C247-249 is a two-phase counter, not frequency doubling; C250-252 is a two-phase dual-frequency counter; C253-255 is a two-phase counter, 4 times the frequency; D register: D0-D7999, power-off saving range can be set to d0-7999, V, Z indirection pointer: V0-7, Z0-7 P subroutine jump number: P0-63 J 'interrupt: X0-5 external interrupt. Timer interrupt (1MS). The counter is interrupted. Special M components: M8000 is normally closed when operating, M8002 is electrical pulse, M8011 is 10Ms pulse, M8012 is 100Ms pulse, M8013 is 1s pulse, M8014 is minute pulse. Package List: 1x PLC Control Board
-
Fruugo ID:
298495483-668053386
-
EAN:
338416393080