Programmable Controller Module Robust Offline Sequence Controller for Industrial Automatic Control DC12‑24V

$64.00
免费送货

Programmable Controller Module Robust Offline Sequence Controller for Industrial Automatic Control DC12‑24V

  • 品牌: Unbranded

Programmable Controller Module Robust Offline Sequence Controller for Industrial Automatic Control DC12‑24V

  • 品牌: Unbranded
建议零售价: $84.00
价格: $64.00
您节省了: $20.00 (23%)
由……售出:
$64.00
免费送货

有货

我们接受以下付款方式

描述

Feature: 1. PROGRAMMABLE FUNCTION: This offline sequence controller has programmable function, which can be customized to set up a great sequence trace according to actual requirements. 2. BASIC VALUES: This programmable offline sequence controller has an operating voltage of DC12 to 24V, a screen structure of 5 digits and a high brightness digital tube. 3. USE SCENARIO: Our programmable off line serial controller is widely applied in industrial automation control, small mechanical devices. 4. MADE OF PC MATERIAL: The programmable offline sequence controller is made of PC material, which is strong and durable. 5. LIGHT WEIGHT: Our programmable offline sequence controller is light weight and easy to install and very practical and helpful. Specification: Item Type: Programmable controller Material: PC Housing Size: Approx. 99.7 x 72 x 17mm / 3.93 x 2.83 x 0.67in (L x W x H) Screen Structure: 5 digit, high brightness digital tube Operating Environment: -5℃- 60℃ (no condensation) Working Voltage: DC12-24V, >1.5A, power supply Opening Size: Approx. 92 x 69.8mm / 3.62 x 2.75in (L x W) Output: 5 outputs <0.8A, output voltage 0V Input: 5 programmable inputs, 2 fixed inputsSerial numberFunctionRangeDefault valueF0Cycle working times Unit: times (demonstrated below) 0-65534, 65535 for countless times1F1Number of rows at the beginning of the loop Unit: rows (Demonstrated below)0-400If the number of lines at the beginning of the loop > the number of lines at the end of the loop, it is illegal. Will alarmF2Number of rows at the end of the loop Unit: rows (demonstrated below)0-4040Illegal if the number of lines at the beginning of the loop > the number of lines at the end of the loop. Will alarmF3Open [Output] manual debugging interface (restart to exit automatically or press [Return])Introduced below0F4Open [Input] manual debugging interface (restart to exit automatically or press [Return])Introduced below0F5Turn on programming mode (restart to exit automatically)0-10If you do not turn on the programming privileges, it is not possible to change the programming statements and alarm0: Turn off programming privileges (power off automatically changes to 0) 1: Turn on programming privilegesF15Adjust the amplitude value of [overall working time] during operation Unit:second0-65535.999 , 0=no speed change during operation0F16Auto run at power on specified program line: 31-40 lines0-200 Turn off. If turned off, program segment 31-40 lines will automatically act as normal program category1 Power on automatically runs program segment 31-40 lines. 2 The power on automatically works.F17Action when ESC emergency stop key is pressed0-200 Program ends and turns off all outputs 1 Program ends and holds current state2 Program ends and runs program segment lines 31-40If parameter 2 is not selected, then program lines 31-40 automatically act as normal program categoriesF18Selectively switch P interface or F interface 0-301 Off [P interface] on [F interface] 2 On [P interface] off [F interface]3 All off (temporary open: press [Set] key before power on) 0 All onF19Main interface display content 0-200 Realtime working status. Display the total number of working times (not the number of cycles) under standby 1 Displays the number of cycles (not the total number) 2 Displays what line of program the system is runningF20Port filtering time of input port 0-65535120Set again when there is external interference. The higher the value, the slower the response Unit: LevelF21Start or emergency stop button signal filtering time on the panel 0-6553527Set again when there is external interference. The higher the value, the slower the response Unit: LevelF24Restore the factory setting 0-44Note: After changing this parameter, you need to power off and restart1 Restore [F] parameter only 2 Restore [P] parameter only3 Restore all 4 No need to restore 0 or >10: restore all and open self test mode, factory mode (only for factory use) . Package List: 1 x Programmable Controller Note: Prohibited for use in the following industries.1. Iatrical equipment.2. Elevators, fire fight, boiler equipment, power generation equipment, mining equipment and other special industries or life vital areas.
  • Fruugo ID: 391541840-838162431
  • EAN: 7354012144669

产品安全信息

请参阅下面列出的特定于该产品的产品安全信息

以下信息由销售该产品的独立第三方零售商提供。

产品安全标签

CE Mark
安全警告: Warning: Please read the product instructions carefully before use to ensure correct use.
序列号: 7354012144669

配送 & 退货

在 2 天内发货

  • STANDARD: 免费 - 之间的交付 周一 27 十月 2025–周一 03 十一月 2025 - 免费

从 中国 送货。

我们会争取将您订购的产品按照您的规格完整地配送给您。不过,万一您收到不完整的订单,或收到的产品与您订购的不同,或者有其他原因让您对订单不满意,您可以要求全部或部分退货,您将收到相应产品的全额退款。 查看完整的退货政策

产品合规详细信息

请参阅下面概述的针对该产品的合规性信息。

以下信息由销售该产品的独立第三方零售商提供。

制造商:
以下信息概述了在Fruugo销售的相关产品的制造商联系信息。

  • Wuhan Jinxingkai Network Technology Co., Ltd.
  • Wuhan Jinxingkai Network Technology Co., Ltd.
  • No. 1-1, Door 57
  • Shihua Village
  • Qingshan District
  • Wuhan
  • CN
  • 430000
  • goldxinks@163.com
  • 0086 17786498762
  • https://shop01473o1711614.1688.com/page/creditdetail.htm?spm=a261y.7663282.shopNavigation.1.6310755czE9SFQ

欧盟负责人:
以下信息概述了欧盟负责人的联系信息。该负责人是位于欧盟的指定经济运营者,负责有关销售到欧盟的相关产品的合规义务。

  • None
  • Kequ Technology s.r.o.
  • Pražákova 1008/69
  • Štýřice
  • Jihomoravský kraj
  • Brno
  • CZ
  • 63900
  • christopher25106@outlook.com
  • 420608214795