Programmable Controller Module Robust Offline Sequence Controller for Industrial Automatic Control DC12?24V
Item Type: Programmable controller_x000D_
Material: PC_x000D_
Housing Size: Approx. 99.7 x 72 x 17mm / 3.93 x 2.83 x 0.67in (L x W x H)_x000D_
Screen Structure: 5 digit, high brightness digital tube_x000D_
Operating Environment: -5- 60 (no condensation) _x000D_
Working Voltage: DC12-24V, >1.5A, power supply_x000D_
Opening Size: Approx. 92 x 69.8mm / 3.62 x 2.75in (L x W)_x000D_
Output: 5 outputs the number of lines at the end of the loop, it is illegal. Will alarm_x000D_
F2Number of rows at the end of the loop Unit: rows (demonstrated below)0-4040_x000D_
Illegal if the number of lines at the beginning of the loop > the number of lines at the end of the loop. Will alarm_x000D_
F3Open [Output] manual debugging interface (restart to exit automatically or press [Return])Introduced below0_x000D_
F4Open [Input] manual debugging interface (restart to exit automatically or press [Return])Introduced below0_x000D_
F5Turn on programming mode (restart to exit automatically)0-10_x000D_
If you do not turn on the programming privileges, it is not possible to change the programming statements and alarm_x000D_
0: Turn off programming privileges (power off automatically changes to 0) _x000D_
1: Turn on programming privileges_x000D_
_x000D_
F15Adjust the amplitude value of [overall working time] during operation _x000D_
Unit:second0-65535.999 , 0=no speed change during operation0_x000D_
F16Auto run at power on specified program line: 31-40 lines0-20_x000D_
0 Turn off. If turned off, program segment 31-40 lines will automatically act as normal program category_x000D_
1 Power on automatically runs program segment 31-40 lines. _x000D_
2 The power on automatically works._x000D_
F17Action when ESC emergency stop key is pressed0-20_x000D_
0 Program ends and turns off all outputs _x000D_
1 Program ends and holds current state_x000D_
2 Program ends and runs program segment lines 31-40_x000D_
If parameter 2 is not selected, then program lines 31-40 automatically act as normal program categories_x000D_
F18Selectively switch P interface or F interface 0-30_x000D_
1 Off [P interface] on [F interface] _x000D_
2 On [P interface] off [F interface]_x000D_
3 All off (temporary open: press [Set] key before power on) _x000D_
0 All on_x000D_
F19Main interface display content 0-20_x000D_
0 Realtime working status. Display the total number of working times (not the number of cycles) under standby _x000D_
1 Displays the number of cycles (not the total number) _x000D_
2 Displays what line of program the system is running_x000D_
F20Port filtering time of input port 0-65535120_x000D_
Set again when there is external interference. The higher the value, the slower the response Unit: Level_x000D_
F21Start or emergency stop button signal filtering time on the panel 0-6553527_x000D_
Set again when there is external interference. The higher the value, the slower the response Unit: Level_x000D_
F24Restore the factory setting 0-44_x000D_
Note: After changing this parameter, you need to power off and restart_x000D_
1 Restore [F] parameter only _x000D_
2 Restore [P] parameter only_x000D_
3 Restore all _x000D_
4 No need to restore _x000D_
0 or >10: restore all and open self test mode, factory mode (only for factory use)
-