Relay Module 32 Functions Safe Reliable Digital Delay Timer Control Switch for DC Motors

$10.95
+ $14.49 送货

Relay Module 32 Functions Safe Reliable Digital Delay Timer Control Switch for DC Motors

  • 品牌: Unbranded

Relay Module 32 Functions Safe Reliable Digital Delay Timer Control Switch for DC Motors

  • 品牌: Unbranded
建议零售价: $35.95
价格: $10.95
您节省了: $25.00 (69%)
由……售出:
$10.95
+ $14.49 送货

有货

我们接受以下付款方式

描述

Item Type:Relay Module_x000D_ Product Model: YF-11_x000D_ Input Voltage:DC7~24V_x000D_ Output Power: Can Control DC Power Load within 10A_x000D_ Time Range: 0.01 Second to 999 Minutes, Any Time Adjustable_x000D_ Function: Pulse Trigger Cycle, Timing, Delay, Power Tube, mos Tube, Field Effect Tube, Switch, Relay Switch_x000D_ Application: It is Often Used to Control Motors, LED Light Strips, DC Motors, Micro Water Pumps, Solenoid Valves, Etc._x000D_ P-21: Give the signal, after a delay of A second, the output starts_x000D_ P-22: Give the signal, after more than A second, the output starts, the signal disappears, and the output stops_x000D_ P-23: After the signal disappears for more than A seconds, the output starts, there is a signal, and the output stops_x000D_ P-24: There is a signal. After A second, the output starts, and after the signal disappears for more than A second, the output stops._x000D_ P-25: When there is a signal, the output will start after A second, and the output will stop when there is another signal for more than A second_x000D_ P-26: There is a signal, the output stops after A second, and the signal disappears and the output stops after A second._x000D_ P-27: Detection of a pulse signal, the output stops; no pulse signal, more than A second output start; (the signal continues or the signal disappears are regarded as no pulse signal)_x000D_ P-28: After power on, after a delay of A second, the output starts until the power is off_x000D_ P-31: After power on, the output starts for A second, stops for B second, infinite loop; power off stops_x000D_ P-32: When there is a signal, start P-31 infinite loop; when the signal disappears, terminate the loop_x000D_ P-33: Give a signal to start P-31 infinite loop; give another signal to terminate the loop_x000D_ P-34: After power-on, after a delay of A second, the output will start, and it will stop after closing B seconds_x000D_ P-35: There is a signal, after a delay of A second, the output will start, and it will stop after the pull-in for B seconds_x000D_ P-36: There is a signal, the output will start after A second, and stop after B second, the signal disappears, and the timer will be cleared and stopped._x000D_ P-37: When there is a signal, the output starts and stops automatically for A second, and then counts for B seconds after it stops. The signal trigger is invalid within A+B time_x000D_ P-38: There is a signal, the output starts and stops automatically for A second, after stopping and counting for B seconds, restarting for A second automatically stops_x000D_ P-41: No action with signal; trigger when signal disappears; disconnect after output start delay A time_x000D_ P-42: The signal disappears, after a delay of time A, the output starts; working time B ends_x000D_ P-43: The signal disappears. After the time A exceeds, the output starts; the working time B ends_x000D_ P-44: After power on, the output will start A time, stop B time; cycle C times and automatically stop._x000D_ P-45: No action when energized, after signal is given; output starts A time, stops B time; cycle C times and automatically stops; Give signal again, execute again_x000D_ P-46: After giving the signal more than A times, the output will start; keep the output; stop when the power is off_x000D_ P-47: After giving the signal more than A times, the output starts and stops for B seconds_x000D_ P-48: Within C seconds, after continuously giving the signal more than A times, the output starts and stops in B seconds_x000D_ 3. Description of button setting:_x000D_ Power on display "" means entering standby state;_x000D_ Press K1 for the first time, (it takes more than 1 second to be effective to prevent false triggering) Display: P -11: K2 adjustment main mode, K3K4 adjustment function_x000D_ Press K1 for the second time, the screen displays: A001: K2 and K3 adjust the first time A, K4 adjusts the decimal point (time unit)_x000D_ Press K1 for the third time, the screen displays: B001: K2 and K3 adjust the second time B, K4 adjusts the decimal point (time unit)_x000D_ Press K1 for the fourth time, the display "" means entering the standby state_x000D_ Press K4 in standby mode to permanently turn off/on the display and switch to low power consumption mode_x000D_ 4. The decimal point time unit description:_x000D_ X.XX The decimal point is in hundreds, and the timing range: 0.01 seconds to 9.99 seconds_x000D_ XX.X The decimal point is in the tenth place, timing range: 0.1 second to 99.9 seconds_x000D_ XXX has no decimal point, timing range: 1 second to 999 seconds_x000D_ XXX. The decimal point is in the ones place, and the timing range: 1 minute to 999 minutes
  • Fruugo ID: 314565398-701223214
  • EAN: 3851969966695

产品安全信息

请参阅下面列出的特定于该产品的产品安全信息

以下信息由销售该产品的独立第三方零售商提供。

安全警告: Do not let your children touch this product alone to avoid swallowing or other injuries.

配送 & 退货

在 3 天内发货

  • STANDARD: $14.49 - 之间的交付 周二 21 十月 2025–周二 28 十月 2025

从 中国 送货。

我们会争取将您订购的产品按照您的规格完整地配送给您。不过,万一您收到不完整的订单,或收到的产品与您订购的不同,或者有其他原因让您对订单不满意,您可以要求全部或部分退货,您将收到相应产品的全额退款。 查看完整的退货政策

产品合规详细信息

请参阅下面概述的针对该产品的合规性信息。

以下信息由销售该产品的独立第三方零售商提供。

制造商:
以下信息概述了在Fruugo销售的相关产品的制造商联系信息。

  • 91440300MA5HDL2A4K
  • SHEN ZHEN SHI LAI LI ZHU BAO SHI PIN MAO YI YOU XIAN GONG SI
  • Room B, 21F, Block A, Jingang Huating, 4009 Baoan Avenue, Yantian Community, Xixiang Street, Baoan District, Shenzhen
  • Shenzhen
  • CN
  • 518102
  • 939301410@qq.com
  • 15625700418

欧盟负责人:
以下信息概述了欧盟负责人的联系信息。该负责人是位于欧盟的指定经济运营者,负责有关销售到欧盟的相关产品的合规义务。

  • 950891051
  • MJCM SARL
  • 78 avenue des Champs Elysees Bureau 326, 75008 Paris, France
  • Paris
  • FR
  • 75008
  • mjcm190928@gmail.com
  • 0033 767213611