描述
SAKO 3PH AC380V Input AC0‑380V Output Variable Frequency Drive Inverter Controller Converter for Lathe Fan Motor 11KW 15HP
Item Type: Variable Frequency Drive
Material: Flame Retardant ABS
Model: SKI90 011G, 015P 4
Input: 3PH AC380V±15% 26A 50 to 60Hz
Output: 3PH AC0 380V 25A 0 to 400Hz
Power Supply Capacity: 17KVA
Applicable Motor: 11KW 15HP
Category
Terminal symbols
Segment Name
Function description
Power Supplies
10V GND
External and 10V Power supply
Provides and 10V external power supply, maximum output current: 150mA (with short circuit protection)
Generally used as an external potentiometer working power supply.
Potentiometer resistance range: 1kΩ to 5kΩ
24V COM
External and 24V power supply
External and 24V power supply, generally used for digital input and output terminals
Power supply and external sensor power supply
Maximum output current: 200mA
Analogue terminals
Al1 GND
Analog input terminal 1
1. Input range: DC0V to 10V 0mA to 20mA, determined by parameter
P437 determines
2. Input impedance: 22kΩ for voltage input, 500Ω for current input
500Ω
AI2 GND
Analog input terminal 2
1. Input range: DC0V to 10V 0mA to 20mA, determined by parameter
P4 to 37 determines
2. Input impedance: 22kΩ for voltage input, 500Ω for current input
500Ω
AO1 GND
Analog output terminal 1
Output voltage range: 0V to 10V
Output current range: 0mA- to 20mA, 4 to 20mA (P5 to 23 selectable)
AO2 GND
Analog output terminal 2
Output voltage range: 0V to 10V
No current output function
J1 jumper cap on isolated main control board to AO2 position, non isolated main control board does not have this function.
This function is not available on non isolated main control boards.
Digital inputs
X1 COM
Digital input 1
HD1 (X5), in addition to the features of X1 to X4, can also be used as a high speed pulse input channel.
Maximum input frequency: 50kHz
1. Input impedance: 1kΩ
2. Voltage range at level input: 5V to 30V
X2 COM
Digital input 2
X3 COM
Digital input 3
X4 COM
Digital input 4
HDI COM(X5 terminal)
Digital input 5
High speed pulse input terminals
A+B-
RS485 communication
A+ is the positive input for the differential signal of 485 communication, B- is the negative input for the differential signal
Digital Outputs
Y1 COM
Open collector output
When used as open collector output terminal (J1 jumper cap to AO2 position on 90 isolated main control board)
HDO COM
High speed pulse output
Subject to function code P5 00 HDO terminal output mode selection when used as high speed pulse output up to 50kHz, when used as open collector output, same specifications as Y1.
K1A K1B K1C
Relay 1 terminal
Contact description:
A: Common point
B: Normally closed point
C: Normally open
Contact drive capability:
AC 250V, 3A, C0Sφ=0.4.
DC 30V, 1A
-