描述
Feature:1. Dual Output: The control module adopts dual relay outputs, which can control temperature and humidity, meeting various needs.2. Automatic Recognition: When the start temperature is greater than the stop temperature, enter cooling mode C; When the start temperature is lower than the stop temperature, enter heating mode H.3. Cooling Mode: When detection temperature is start temperature, the cooling equipment starts working; When detection temperature is stop temperature, the cooling equipment stops working.4. Heating Mode: When detection temperature is start temperature, the heating equipment starts working; When detection temperature is stop temperature, the heating equipment stops working.5. With Indicator Light: The temperature and humidity controller is designed with indicator light and the working status is clear and intuitive.Specification:Item Type: Temperature Humidity ControllerMaterial: ABSModel: XY WTH1Temperature Measurement Range: -20 to 60Humidity Range: 00% to 100% RHControl Accuracy: 0.1 0.1% RHDetection Probe: Integrated sensorOutput Type: Relay outputOutput Capacity: Up to 10ATemperature Correction Function OFE (-10.0 to 10.0):If the system works for a long time, there may be deviations. By using this function to correct, the actual temperature=measured temperature+calibration value;How to set the start and stop temperature:1. In the running interface, press and hold the TM+ key for more than 3 seconds to enter the startup temperature setting interface. Testing can be done by modifying parameters using the TM+ TM- key. After the parameter modification is completed, wait for 6 seconds to automatically exit and save.2. In the running interface, press and hold the TM- key for more than 3 seconds to enter the stop temperature setting interface. Testing can be done by modifying parameters through the TM+ TM- key. After the parameter modification is completed, wait for 6 seconds to automatically exit and save.The humidity function is as follows:1. Automatic recognition of working mode:Automatically identify the working mode based on start or stop humidity.Start humidity > stop humidity, dehumidification mode d ; Start humidity < stop humidity, humidification mode E.2. Dehumidification mode:When the detection humidity is start humidity, the relay is connected, the green indicator light is on, and the dehumidification equipment starts working.When the detection humidity is stop humidity, the relay is closed, the green indicator light is off, and the dehumidification equipment stops working.3. Humidification mode:When the detection humidity is start humidity, the relay is connected, the green indicator light is on, and the humidification equipment starts working.When the detection humidity is stop humidity, the relay is closed, the green indicator light is off, and the humidification equipment stops working.4. Humidity correction function RH (-10.0 to 10.0):If the system works for a long time, there may be deviations. By using this function to correct, the actual humidity=measured humidity+calibration value.How to set start and stop humidity:1. In the running interface, press and hold the RH+ key for more than 3 seconds to enter the startup humidity setting interface. During testing, parameters can be modified using the RH+ RH- key. After the parameter modification is completed, wait for 6 seconds to automatically exit and save.2. In the running interface, press and hold the RH- key for more than 3 seconds to enter the stop humidity setting interface. Testing can be done by modifying parameters using the RH+ RH- key. After the parameter modification is completed, wait for 6 seconds to automatically exit and save..Package List:1 x Temperature Humidity Controller
-
Fruugo ID:
420604219-886225227
-
EAN:
7847689963690