W3230 Relay Output Digital Temperature Controller -55~120c Thermostat Regulator Heating Cooling Control Switch 10a 220v/20a 12v

$26.95
免费送货

W3230 Relay Output Digital Temperature Controller -55~120c Thermostat Regulator Heating Cooling Control Switch 10a 220v/20a 12v

  • 品牌: Unbranded

W3230 Relay Output Digital Temperature Controller -55~120c Thermostat Regulator Heating Cooling Control Switch 10a 220v/20a 12v

  • 品牌: Unbranded
建议零售价: $64.00
价格: $26.95
您节省了: $37.05 (57%)
由……售出:
$26.95
免费送货

有货

我们接受以下付款方式

描述

Dear customer: Thank you for choosing my store for shopping. The following are the matters needing attention for shopping: A. Economic transportation: detailed tracking information will not be included. Most of the packages will cause delayed delivery within the expected delivery time, so you need to be patient B. Each product link: There will be different option variants. If you do nt know how to select the product you want, please contact me, I will be honored to solve this problem for you. C. When you receive the package, there is product damage / product problem / error product and shipping problem, please contact me in time, I will solve it for you D. If you are a wholesaler / distributor, a large number of orders and quantities, to provide you with factory prices, and hope to be honored to reach a partner with you GOOGZON store: I wish you a happy life Power Supply:DC 12V/ AC 110V-220V Temperature Control Range:-55-120 Resolution Ratio: 0.1C(-9.9-99.9); 1C(other range) Color of Displaying: red/blue Measurement accuracy: 0.1C Control accuracy: 0.1C Sensor: NTC10K Waterproof sensor Output: Relay Contact Capacity 20A 12V / 10A 220V Environmental requirements: -10-60C , humidity 20%-85%RH Dimension:79mm *43mm*26mm Cutting Size:73mm*39mm Sensor wire: 1 meter Method of Use At this time, the display is displayed as measuring temperature. Press the SET key once and the display temperature flashes. Press +- to SET the required temperature (+- can quickly rise and fall) After the setting is complete, press Set to confirm and return. The output of the thermostat is 20A relay, which can meet various high-power loads. If the control circuit is well connected, it can supply power to the thermostat. At this time, the display screen displays the ambient temperature. Indicator and nixie tube status description Indicator: Blinking indicates delay in starting cooling or heating. Steady on indicates that the relay is closed Digital tube: display LL for the sensor open circuit, please connect the sensor according to the instructions; If HH is out of the measuring range, the thermostat will disconnect the relay forcibly. Display -- high temperature alarm Parameter Function Description Long press SET for 5 seconds to enter the main menu setting, press +- to switch to P0... P6, long press SET or 10 seconds no key action controller automatically confirm return. P0 cooling and heating mode Long press SET for 5 seconds to display P0, press SET once to SET the working mode, press +- to switch [H for heating mode] [C for cooling mode], press SET once to return, long press Set or 10 seconds without key action the controller will automatically confirm completion. Refrigeration mode: when the temperature measurement value is greater than or equal to the temperature setting point, the refrigeration relay draws, and the refrigerator starts; When the temperature measurement value is less than the temperature setting point-return difference, the refrigeration relay is disconnected and the refrigerator is closed. Heating mode: When the temperature measurement value is less than the temperature setting point, the heating relay draws and the heater starts; When the temperature measurement value is greater than or equal to the temperature setting point + return difference, the heating relay is disconnected and the heater is closed. P1 back error setting Press +- to switch to P1. Press SET once to SET the return difference value. Press +- to SET the return difference value to 0.1-15. Refrigeration mode: when the temperature measurement value is greater than or equal to the set value, the relay suction, the refrigerator starts; When the temperature measurement value is less than the set value - return value, the relay is disconnected and the cooler is closed. For example, when the environment is 30, the set value is 25, and the return difference is 2. After power on, the closed refrigerator of the relay starts. When the refrigeration reaches 23, the refrigerator of the relay will be disconnected and shut down. Heating mode: when the temperature measurement value set value, relay suction, heater start; When the temperature measurement value is not less than the set value + return value, the relay is disconnected and the heater is closed. For example, when the environment is 10, the set value is 25, and the return difference is 2. After power-up, the closed heater of the relay will start. When the heater is heated to 27, the relay will disconnect and the heater will close. P2 Set the upper limit for the maximum temperature In order to avoid the danger of oversetting the temperature due to misoperation by others, the thermostat has the maximum setting upper limit function, which limits the setting range of the maximum temperature setting point controlled by the thermostat. Press +- to switch to P2. Press SET once to SET the maxi
  • Fruugo ID: 207443356-441553949
  • EAN: 9492864243913

产品安全信息

请参阅下面列出的特定于该产品的产品安全信息

以下信息由销售该产品的独立第三方零售商提供。

产品安全标签

CE Mark
安全警告: WARNING: TO AVOID DANGER OF SUFFOCATION, KEEP THIS PLASTIC BAG AWAY FROM BABIES AND CHILDREN.

配送 & 退货

在 24 小时内发货

  • STANDARD: 免费 - 之间的交付 周二 30 九月 2025–周三 08 十月 2025 - 免费

从 中国 送货。

我们会争取将您订购的产品按照您的规格完整地配送给您。不过,万一您收到不完整的订单,或收到的产品与您订购的不同,或者有其他原因让您对订单不满意,您可以要求全部或部分退货,您将收到相应产品的全额退款。 查看完整的退货政策

产品合规详细信息

请参阅下面概述的针对该产品的合规性信息。

以下信息由销售该产品的独立第三方零售商提供。

制造商:
以下信息概述了在Fruugo销售的相关产品的制造商联系信息。

  • CREA
  • CREA
  • 1-3 Boulevard Charles de Gaulle Colombes 92700 FR
  • Colombes
  • FR
  • 92700
  • xmchymx@outlook.com
  • 86-13312976782

欧盟负责人:
以下信息概述了欧盟负责人的联系信息。该负责人是位于欧盟的指定经济运营者,负责有关销售到欧盟的相关产品的合规义务。

  • E-CrossStu GmbH
  • E-CrossStu GmbH
  • Mainzer Landstr.69,60329 Frankfurt am Main,Hessen, Deutschland
  • Frankfurt am Main
  • DE
  • 60329
  • E-CrossStu@web.de
  • +4969332967674