描述
1It is widely used in agricultural greenhouses, flower cultivation and other occasions requiring light intensity, temperature and humidity monitoring. 2Wall-mounted, easy installation, and the small volume will help saving your space. 3Compact and portable design, high density material shell, closed moisture-proof effect is significant. 4Exquisite welding circuit board, automatic manipulator welding process, to ensure the circuit board signal stability and accuracy, long-term reliable. 5High quality optical components, close to the visual sensitivity of the spectral characteristics, a wide range of luminance can be determined by 1 lx with high precision. 6With 485 communication, standard modbus-rtu communication protocol, communication address and baud rate can be set, the maximum communication distance is 2000m/6561.7ft. 7Powered by 0-30V DC wide voltage, low power consumption, energy saving. 8Waterproof design, it can be used indoors and outdoors to meet more needs of customers.
Condition: 100% Brand New
Item Type: Light Intensity Temperature Humidity Transmitter
Material: Polyester Plastics
Color: As shown in the picture
Size: Approx.13x11.7x5.5cm / 5.1x4.6x2.2in
Weight: Approx.208g/7.3oz
DC Power Supply (default): 10-30V DC
Maximum Power Consumption: 0.4W
Humidity Accuracy: 3%RH (5%RH~95%RH, 25C)
Temperature Accuracy: 0.5C (25C)
Light intensity Accuracy: 7% (25C)
Light Intensity Range: 0-200,000 Lx
Temperature and Humidity Range: -40 C ~ +60 C, 0% RH ~ 80% RH
Long-term Stability Temperature: 0.1C/y
Long-term Stability Humidity: 1%/y
Long-term Stability Light Intensity: 5%/y
Response Time Temperature: 18s (1m/s wind speed)
Response Time Humidity: 6s (1m/s wind speed)
Response Time Light Intensity: 0.1s
Basic Communication Parameters:
v:* {behavior:url(
default
VML);}
o:* {behavior:url(
default
VML);}
x:* {behavior:url(
default
VML);}
.shape {behavior:url(
default
VML);}
Coding
8 bits binarysystem
Data bits
8 bits
Parity check bit
None
Stop bit
1 bit
Error check
CRC(redundant cyclic code)
Baud rate can be set
2400bit/s,4800bit/s and 9600 bit/s can be set, and the factory default is 4800bit/s
Data Frame Format Definition:
Adopt Modbus-RTU communication protocol, the format is as follows:
Initial structure 4 bytes of time
Address code = 1 byte
Function code = 1 byte
Data area = N bytes
Error check = 16-bit CRC code
End structure 4 bytes of time
Address Code: is the address of the transmitter, which is unique in the communication network (factory default 0x01).
Function Code: The instruction function of the command sent by the host. This transmitter only uses function code 0x03 (read register data).
Data Area: The data area is the specific communication data. Note that the 16bits data high by
-
Fruugo ID:
182883622-390413566
-
EAN:
889610310354