XH3002 Microcomputer Digital Temperature Controller Hatching Temperature Controller24V

$16.95
免费送货

XH3002 Microcomputer Digital Temperature Controller Hatching Temperature Controller24V

  • 品牌: Unbranded

XH3002 Microcomputer Digital Temperature Controller Hatching Temperature Controller24V

  • 品牌: Unbranded
建议零售价: $21.95
价格: $16.95
您节省了: $5.00 (22%)
由……售出:
$16.95
免费送货

有货

我们接受以下付款方式

描述

Feature:1. A variety of fields perfect use, convenient operation and practical settings, is your side temperature control housekeeper.2. It is precise and reliable with good longterm stability. Convenient for install and fixed. Small size, low power consumption, fast response.3. Easy operation, to set start temperature, stop temperature, corrected temperature connector and so on.4. Suitable for hatching, breeding, air and water temperature control and other related temperature detection and control.5. Specifications are optional, precise temperature control, temperature calibration.Specification:ItemType: Digital Temperature ControllerMaterial: PlasticWeight: Approx. 51g / 1.8ozOperating Voltage Specifications: 12V, 24V, 110-220VAccuracy Level: 0.1Temperature Measurement Range: -50-110 ()Temperature Measurement Accuracy: -15-65 ()Humidity Measurement Accuracy: 1 (RH)Temperature Measurement Error: 1 ()Applicable Environment: -15-55 / 20%-85%RHProduct Embedded Hole Size: 73mm / 2.9in, Hole Diameter (4mm)How to use:1. Press the setting button once to enter the internal menu, the default display is P0, press the setting button again, and set the required starting temperature through the up and down buttons.2. Press the setting key once to enter the internal menu, the display is P0, switch to P1 through the up and down keys, press the setting key again, and set the required stop temperature through the up and down keys.3. Enter the internal menu in the same way, switch to P2 through the up and down buttons, press the setting button again, and set the required calibration temperature through the up and down buttons. (Note: In the setting, if the detected temperature value is 0.5C larger than the actual temperature value, then the calibration temperature that needs to be set is -0.5C. If the detected value is 1C lower than the actual temperature value, the calibration temperature that needs to be set is 1C. Detection temperature + Correction temperature = Actual temperature.)4. Enter the internal menu in the same way, switch to P3 by pressing the up and down buttons, press the setting button again, and set the required delay time through the up and down buttons in minutes. (Note: Delayed start is generally used for compressor refrigeration. If it is used for refrigerators and freezers, this value needs to be set. According to the compressor back pressure, the general setting value is 3-6 minutes. If you are not used for control or no delay function is needed, just skip it.Temperature control mode1. Setting essentials:Start temperature <stop temperature (the program automatically judges that the working mode is heating mode)2. Setting method: press the setting key to enter the internal menu, set the start temperature through the P0 value, and set the stop temperature through the P1 valueUse case: Control the water heater, stop heating to 50C, and start heating again when the temperature returns to 40C, how to set it?1. Make sure that the working mode is heating mode, starting temperature <stop temperature.2. Press the setting key to enter the internal menu, select P0 to start the temperature and set the P0 value to 40C.3. Press the set key to enter the internal menu, select P1 to stop the temperature and set the value of P1 to 50Cooling mode1. Setting essentials: start temperature> stop temperature (the program automatically judges that the working mode is cooling mode)2. Setting method: Press the setting key to enter the internal menu, set the start temperature through the P0 sets the stop temperature through the P1 value.Use case: empty cabinet radiator, heat dissipation stops at 26, and the temperature rises to 30 to start the radiator again, how to set it?1. Make sure the working mode is cooling mode, starting temperature>stop temperature.2. Press the setting key to enter the internal menu, select P0 to start the temperature change and set the P0 value to 30C.3. Press the setting key to enter the internal menu, select P1 to stop the temperature and set the value of P1 to 26..Package List:1 xTemperature Controller Note:1. Press and hold the up and down keys at the same time, wait until the screen displays 888 to restore the factory settings.2. The screen displays LLL, indicating that the temperature probe is not plugged in, disconnected, or damaged, just replace it.3. The screen display HHH indicates that the temperature probe is short‑circuited and exceeds the temperature detection range.
  • 品牌: Unbranded
  • 类别: 服务
  • Fruugo ID: 426736175-895888068
  • EAN: 7708428574778

产品安全信息

请参阅下面列出的特定于该产品的产品安全信息

以下信息由销售该产品的独立第三方零售商提供。

产品安全标签

CE Mark
安全警告: Warning: Please read the product instructions carefully before use to ensure correct use.
序列号: 7708428574778

配送 & 退货

在 2 天内发货

  • STANDARD: 免费 - 之间的交付 周一 03 十一月 2025–周五 07 十一月 2025 - 免费

从 中国 送货。

我们会争取将您订购的产品按照您的规格完整地配送给您。不过,万一您收到不完整的订单,或收到的产品与您订购的不同,或者有其他原因让您对订单不满意,您可以要求全部或部分退货,您将收到相应产品的全额退款。 查看完整的退货政策

产品合规详细信息

请参阅下面概述的针对该产品的合规性信息。

以下信息由销售该产品的独立第三方零售商提供。

制造商:
以下信息概述了在Fruugo销售的相关产品的制造商联系信息。

  • Shenzhen Mutalai Technology Co., Ltd.
  • Shenzhen Mutalai Technology Co., Ltd.
  • 71001-187, 7/F, Building D, Gaoke Mansion, No. 2076 Yuanyuan Avenue
  • Nanshan Street
  • Nanshan District
  • Shenzhen
  • CN
  • 518000
  • gbyhynnygt@126.com
  • 18664978705
  • https://detail.1688.com/offer/593788918206.html?spm=a2615.7691456.autotrace-offerGeneral.7.4cc915345wLsDx

欧盟负责人:
以下信息概述了欧盟负责人的联系信息。该负责人是位于欧盟的指定经济运营者,负责有关销售到欧盟的相关产品的合规义务。

  • None
  • Kequ Technology s.r.o.
  • Pražákova 1008/69
  • Štýřice
  • Jihomoravský kraj
  • Brno
  • CZ
  • 63900
  • christopher25106@outlook.com
  • 420608214795
  • https://www.noon.com/uae-en/p-29378/